SEERS Medical products comply with the Essential Requirements in Annex I of EC Directive 93/42/EEC, with all relevant design, production records, risk assessments, product testing and labelling information recorded in the documentation file labelled the “Technical File”.
All products lift the rated SWL smoothly from the minimum height to the maximum height
Comply with IEC 60601-1 Safety for Medical Electrical Equipment
Upholstered couch sections comply with flammability requirements of BS 7176:1995 (medium hazard) using ignition sources 0 (cigarette) and 1 (gas) defined in BS EN 1921-1 2,5 (crib) BS 5852:1990
![]() | Quality SystemsSEERS Medical were accredited with ISO 9001:2008 quality management system in 2015 in recognition of our ability to prove consistent provision of products and services that meet the needs of our customers. ISO 14001 accreditation was also awarded for SEERS Medical’s environmental management system. |
![]() | WarrantyAll SEERS Medical treatment couches, manufactured during or after September 2017, feature a lifetime frame warranty and a five year warranty on all other components. |
![]() | Electrical SafetyAll SEERS Medical products comply to EN 60601- 1:2006+A12:2014 (E) the General requirements for basic safety and essential performance. In addition, the actuation and control systems used on our products are marked with the UL mark, demonstrating compliance to UL60601-1 and CAN/CSA-C22.2 No. 601.1-M90, meeting the requirements for USA and Canada. The actuation control system is also marked with approval to C-ETL-US No. 3154358. |
![]() | Mechanical SafetyAll SEERS Medical products have been tested to the applicable EN 60601-1:2006+A12:2014 (E) the General requirements for basic safety and essential performance. Thoroughly tested with a two and a half times SWL (in excess of 600Kg loaded evenly, for in excess of one hour, to prove load support capability without failure. Our products are tested in accordance to Clauses 9.8.3.2-3 Static Forces of EN60601-1:2006 Not only do our products have a high SWL (typically 240Kg), but our products also lift the rated SWL from the minimum height to the maximum height smoothly. |